Hydrogen and inert gas degreasing unit BOG-50

Hydrogen and inert gases degreasing unit BOG-50 is used for hydrogen, inert gas and nitrogen purification from oil vapor impurities. The purification unit functions at the raw gas overpressure of 0.2-0.6 MPa.

For activated coal regeneration the purification unit has to be connected to a centralized forevacuum system or a pump providing ultimate residual pressure not more than 13 Pa. As an adsorbent for oil absorption it its recommended to use 50 liters of activated coal AG-3.

Hydrogen and inert gases degreasing unit BOG-50 can be used both separately (in applications where only degreasing is required) and together with gas purification equipment (in applications requiring deep hydrogen, inert gases and nitrogen purification from moisture, oxygen and dust particles.)

Operation of the degreasing unit is based on the principle of oil vapors adsorption by activated coal AG-3.

Hydrogen and inert gas degreasing unit BOG-50

Specifications of hydrogen and inert gas degreasing unit BOG-50

 
BOG-50
Operating pressure, kgs/sm2
2-6
Capacity, m3/hour
50
Oil vapor contents in the raw gas, vol.%.
1,0*10-4
Power consumption, kW
2,4
Dimensions, mm
650 x 655 x 1655
Weight, kg
150

Our company Prizma LLC can develop and manufacture hydrogen and inert gas purification units to your specifications. Please let us know the parameters (chemical analysis) of your raw gas and what pressure, capacity and gas-purity value you want to receive at the output of your gas purification unit.